Paguro Acoustic Marine Generators. The Paguro range of marine generators ranges from 2 – 18kVA. We are therefore able to fulfil a large variety of power generation requirements to suit both yachts and motorboats. Give us a call on to discuss your marine power solutions. The perfect balance. Paguro generators are compact and powerful. Paguro generators are labelled by continuous KVA / KW There are three ways marine 230V generators commonly make power, ‘synchronous’, ‘permanent magnet’ and ‘asynchronous’. ‘Synchronous’ is the most popular due to its inherent ability to cope with short but very high demand for current, to start such machines as air-conditioning units and water-makers.
- Paguro Generator Technical Manual Transfer Switch
- Paguro Generator Service Manual
- Technical Manual Definition
- Paguro Generator Technical Manual Pdf
Product Description
Paguro Generator Technical Manual Transfer Switch
The Paguro 2000 Compact is an energy saving marine generator that is built for smaller boats, allowing you to take advantage of a system that comes with on demand AC power. Using only 0.35 litres of diesel per kW used per hour, the Paguro 2000 Compact is encased in an enhanced triple skin soundproof capsule with advanced internal and external anti-vibration feet, keeping the peace by reducing noise and vibration. The Paguro 2000 Compact is also ideal for running TVs, Laptops and other devices by providing a clean sine wave and is a perfect companion for heavy power consuming equipment such as air conditioning with a start load capability of over 200%. In addition, it’s simple to operate thanks to its easy to read remote control panel including power monitor and 13m cable.
- Sound capsule | Ext anti-vibe mounts | Remote panel & harness | Spare Impeller Kit
- 2.0kW Output
- Voltage - 230V @ 50Hz
- 3000rpm
- Diesel
- Weight - 51kg
- Dimensions - 470 x 400 x 475 | (LxWxH)
Contact us by phone or email for more information.
MANUALS & GUIDES
*If you have trouble opening the pdf file, please try installing Adobe Acrobat reader on your device.
Related Products
- Paguro 6000 Marine Generator£7,140.00
- Paguro 9000V Marine Generator£9,360.00
- Paguro 12000V Marine Generator£11,160.00
- Paguro 14000 Marine Generator£10,224.00
- Paguro 18000 Marine Generator£11,316.00
Customers Who Viewed This Product Also Viewed
- Paguro 3 SY Marine Generator£5,136.00
- Paguro 4 SY Marine Generator£5,304.00
- Paguro 6000 Marine Generator£7,140.00
- Paguro 18000 Marine Generator£11,316.00
Find Similar Products by Category
Power Products » 2kW Military Tactical Generators
Paguro Generator Service Manual
Pictured Left: 2kW 120V AC MTG P/N 95-531, Pictured Right: 2kW 28V DC MTG P/N 95-501
Since 1996 Dewey Electronics has been manufacturing and supplying the standard 2kW Military Tactical Generator to the US Department of Defense’s PM-Mobile Electric Power (PM-MEP). We have fielded over 17,000 MTGs in this open frame configuration.
Technical Manual Definition
Used by the tri-services (U.S. Army, U.S. Navy/U.S.M.C., and U.S. Air Force), it is supported with a full logistic package in the DoD inventory.
Our heavy fuel generators operate on diesel fuels and military fuels (JP-8) and meet all the requirements of Purchase Description PD 6115-0111, dated 1 February 2001.
These compact, portable, highly reliable, lightweight units are available with either 120V AC or 28V DC output and have established themselves as the mainstay of portable power for military applications worldwide. Their open frame configuration allows them to be easily lifted, stacked, or transported by any military vehicle. This open configuration contributes to the ease of maintenance for which these units are noted.
Paguro Generator Technical Manual Pdf
Equipped with a manual recoil starter and the ability to be electrically started from their NATO Slave Connector, these units are used throughout the military where pure military power is a requirement or when portability is a necessity. Now these units are available directly from Dewey Electronics.
The open frame configuration is available as follows:
Power Output | Dewey Model | PM-MEP Model | NSN | P/N |
28V DC | -501A | MEP95-501A | 6115-01-435-1567 | 95-501 |
120V 60Hz | -531A | MEP95-531A | 6115-01-435-1565 | 95-531 |
Environmental Specification Summary
Requirement | Mil-Std- | MEP-501A | MEP-531A |
High Temperature – Operation (Derated Power 1.9kW) | 705, TM 710.1 | 49°C/120°F | 49°C/120°F |
Cold Temperature – Starting & Operating | 705, TM 701.1 | -40°C/-40°F | -40°C/-40°F |
705, TM 701.2 | -25°C/-13°F | -25°C/-13°F | |
705, TM 701.4 | -5°C/+23°F | -5°C/+23°F | |
Altitude (Full Rated Power 2kW) | 705, TM 720.1 | 1219 m @ 35°C 4000 ft @ 95°F | 1219 m @ 35°C 4000 ft @ 95°F |
Altitude (Derated Power 1.6kW) | 705, TM 720.1 | 2438 m @ 35°C 8000 ft @ 95°F | 2438 m @ 35°C 8000 ft @ 95°F |
Humidity | 705, TM 711.1 | 0-100% | 0-100% |
Ice Glaze and Wind (tailored) (1.3 mm/0.5 inch) Ice glaze start & run one hour | Temperature: Wind Speed: | -23 to 0°C/-10 to 32°F 22.5 m/s (73 ft/s) | -23 to 0°C/-10 to 32°F 22.5 m/s (73 ft/s) |
Rain (tailored) | 100 mm (3.9 in/hr) 30 min/side with wind speed 18m/s (40 mph) | 3 hours exposure last hour operational per Mil-Std-705,TM 608.1 | 3 hours exposure last hour operational per Mil-Std-705, TM 608.1 |
Road (tailored) Truck or Trailer Transportation | Road Course: | Distance: | Speed: |
Paved Highway | 250 miles/402 km | 50mph/80 km/hr | |
Perryman 1 | 250 miles/402 km | 20 mph/32 km/hr | |
Churchville B | 125 miles/201 km | 20 mph/32 km/hr | |
Belgian Block | 15 miles/24 km | 20 mph/32 km/hr | |
Salt Fog (tailored –two 48 hour cycles) | 35°C/95°F | 5% solution | 5% solution |
Sand and Dust (tailored 1.4 grams/m3 33.2 km/hr) | Four 90 minute exposures | Operate last 10 minutes each exposure | Operate last 10 minutes each exposure |
Solar Radiation (tailored) | One 24 hour cycle | 355 BTU/ft2 | 355 BTU/ft2 |
Electromagnetic Interference | Tailored | ||
Conducted Emissions (Power Leads) | 15 kHz to 2 MHz | 78/log(75/104)xlog(f/2)+60 dBµA/MHz | 78/log(75/104)xlog(f/2)+60 dBµA/MHz |
2 MHz to 50 MHz | Waived | 60 dBµA/MHz | |
Broadband Radiated Emissions | 14 kHz to 25 MHz | 25/log(56/105)x(log(f/25)+100 dBµV/MHz | 25/log(56/105)x(log(f/25)+100 dBµV/MHz |
25 MHz to 80 MHz | 30/log(3125/104)xlog(f/25)+100 dBµV/MHz | 30/log(3125/104)xlog(f/25)+100 dBµV/MHz | |
80 MHz to 1 GHz | 70 dBµV/MHz | 70 dBµV/MHz | |
Radiated E-field | 2 to 400 MHz | 10 V/m | 10 V/m |
400 MHz to 10 GHz | 5 V/m | 5 V/m |
Physical Characteristics
Description | MEP-501A | MEP-531A |
Size | 29.5 inches X 16.0 inches X 21.7 inches | 29.5 inches X 16.0 inches X 21.7 inches |
Weight | 140 lb with 4 hours of fuel | 152 lb with 4 hours of fuel |
Instrument Gages | Analog Voltmeter | Analog Voltmeter |
Analog Load Meter | Analog Load Meter | |
Analog Frequency Meter | ||
Engine Hour Meter | Electro-mechanical Digital | Electro-mechanical Digital |
Circuit Breaker | 28V @ 82 Amps | 120V @ 20 Amps |
Connectors | NATO SLAVE Receptacle | NATO SLAVE Receptacle |
Terminals | Split Lug Load Terminals ( +/-) | Split Lug Load Terminals (L/N) |
Receptacle | GFCI Duplex 15 Amp |